Minimum Order Quantity | 10 Piece |
Brand | Sensus |
Voltage | 100 - 240 VAC |
Standards | EN 1434, EN 61000-6-1, EN 61000-6-2, EN 61010, DIN 43863-5 |
Operating Altitude | Up To 2,000 M Above Sea Level |
Installation Side | Hot Or Cold Side |
Display Unit | energy kWh, MWh, MJ, GJ |
Maximum Resistance | - 837 Ohm at 24 VDC, 0 Ohm at 6 V |
Dimensions | B x H x T = 120 x 163 x 49 mm |
Ambient Temperature | +5 ... +55 Degree Celsius , EN 1434 class C |
Storage Temperature Range | 0...60 Degree Celsius |
Temperature Difference | 3...175 K |
Frequency | 50/60 Hz |
Backup Battery Real Time Clock | 3.6 V Lithium Battery |
Model Name | PolluWatt |
Terminals | 1.5 mm2 Spring Terminals, Power Connection 2.5 mm2 Screw Terminals |
Temperature Measuring Range | 5...+180 Degree Celsius (Heat Carrier: Water) |
Pulse Value Of The Flow Sensor | 0.001 ... 9999.999 Litre |
Data Backup In The Event Of A Power Failure | In EEPROM >10 Years |
Calculation Cycle | 1 s |
Humidity Max. | 95% Rel. Humidity (Non-condensing) |
Protection Rating | IP 54 |
Country of Origin | Made in India |
Use the PolluWatt Duo II to complete the heat measuring point with almost all the usual volume measuring units and temperature sensors that are currently used in the field.
Depending on the type and size of the volume measuring unit foreseen, the valence of the incoming volume signal is programmed at the factory before delivery. For measuring points in which the volume measuring unit is built into the heating, PolluWatt Duo II can be acquired as a supply calibrated variant.
For cooling devices there is a variant with national cooling meter approval according to K7.2.
The PolluWatt Duo II is used for energy metering in split systems which are equipped with passive pulsed flow meters and 2-wire or 4-wire Pt500 temperature sensors. In most cases PolluWatt Duo II is used with the following flow sensors:
Benefits to you
PolluWatt Duo II is ideally equipped for use in demanding metering tasks, thanks to:
For more information on this product, please download the data sheet.
Product Details:
Minimum Order Quantity | 10 Piece |
Brand | Sensus |
Type | Digital |
Frequency | 50 Hz |
Voltage | 220 V |
Phase | Single Phase |
Accuracy Class | 2 or 3 per EN 1434 |
Relative Humidity | 95 % |
Energy Consumption Measurement | <10kWh |
Hybrid Meter Temperature Range | Hybrid meter 15 - 90 Degree Celsius (Also as variant 15 - 120 Degree Celsius) |
Cooling Meter Temperature Range | 5 - 50 Degree Celsius |
Ratio | 1:50 |
Temperature Measurement Cycle | 2 / 60 S (Dynamic); With Network Operation 2 sec |
Standard | Modbus (Q1/2021) IEC 61158 |
Minimum Flow | 0.012 m3/Hour |
Permissible Operating Pressure In Bar | 16 |
Permissible Ambient Temperature | 5 - 55 Degree Celsius at 95% RH |
Tariff Registry | 2 Individually Customizable Registers |
Electromagnetic Environmental Conditions | Class E2 |
Protection Class | IP 65 |
Calculator Unit Dimensions | 75 x 110 x 34.5 mm (LxWxD) |
Start-up Value In (Average Value) | 0.006 m3/Hour |
Storage Temperature | -20 - 55 Degree Celsius |
Connection Cable Length | Approx. 0.85 m |
Heating Meter Temperature Range | 15 - 90 Degree Celsius (Also as variant 15 - 130 Degree Celsius) |
Nominal Flow | 0.6 m3/Hour |
Minimum Temperature Difference | > 0.05 K (With Cooling Metering < -0.05) |
Maximum Flow (Short-term) | 1.2 m3/Hour |
Model Name | PolluStat |
Mechanical Environmental Conditions | Class M1 |
Flow Measurement Cycle | 2 s |
Country of Origin | Made in India |
The following modules for remote readout and data communication are available as options and can be retrofitted:
For electronic remote reading of the meters and connection to building automation systems, a series of optional modules are available for the PolluStat series, which can be installed in the factory or retrofitted at any time:
Product Details:
Minimum Order Quantity | 10 Piece |
Display Type | Digital |
Frequency | 50 Hz |
Brand | Sensus |
Pattern Approval | DE-19-MI004-PTB002 |
Model Name | PolluCom F |
Battery Lifetime | Up To 13 Years |
Temperature Range Of The Flow Sensor | 5 to 90 Degree Celsius |
Ideally Applicable For | "6/12 Degree Celsius Cooling Systems |
Country of Origin | Made in India |
A major new feature is that the PolluCom F is now equipped with wireless communication to integrate the energy measurement into your heating network solution.
Besides the data communication, the PolluCom F gives you reliability of the measurements with a technology, which is more than 45 years approved.
Product Details:
Minimum Order Quantity | 10 Piece |
Brand | Sensus |
Battery Lifetime | 6 Years + 1 Year Storing Reserve Optional: 11 Years |
Model Name | PolluTherm |
Required Pulse Duration | > 100 ms |
Closing Time | 125 ms |
Suitable Types Of Temperature Sensors | Pt 500 Two- Or Four-wire Connection |
Electromagnetic Environment | Class E 1 |
Temperature Difference | 3 - 150 K |
Input Pulse Values For Flow Sensors | 1 / 10 / 100 / 1,000 / 10,000 / 0.25 / 2.5 / 25 Or 250 Litres |
Type Of The Pulsers | Reed Switch, Open Collector |
Storing Temperature | - 20 to + 65 Degree Celsius |
Permissible Environmental Temperature | 5 - 55 Degree Celsius |
Optical Data Interface | Physical acc. to EN 61107 Data telegram acc. to EN 1434-3 |
Max. Power | 0.1 A |
Cable Length | 1.5 m |
Temperature Measuring Range | 1-180 Degree Celsius (-20 to 180 Degree Celsius Uncalibrated) |
Protection Class | IP 54 |
Mechanical Environment | Class M 2 |
Approval | acc. EN 1434, Class 2 Directive 2004/22/EG (MID) |
Pulse Input Frequency | < 3 Hz |
Terminal Voltage | 3 V |
Dimensions (Wall Mounting) | 125 x 159 x 52 mm (WxHxD) |
Country of Origin | Made in India |